نبذة مختصرة : In this paper, 3 typical organic fluids were selected as working fluids for a sample slag washing water binary power plants. In this system, the working fluids obtain the thermal energy from slag washing water sources. Thus, it plays a significant role on the cycle performance to select the suitable working fluid. Energy and exergy efficiencies of 3 typical organic fluids were calculated. Dry type fluids (i.e., R227ea) showed higher energy and exergy efficiencies. Conversely, wet fluids (i.e., R143a and R290) indicated lower energy and exergy efficiencies, respectively.
No Comments.