Development of a real-time loop-mediated isothermal amplification assay for detection of porcine circovirus 3

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • بيانات النشر:
      Springer Science and Business Media LLC, 2019.
    • الموضوع:
      2019
    • نبذة مختصرة :
      Background Porcine circovirus type 3 (PCV3) is an emerging circovirus species, that has been reported in major pig-raising countries including the United States, China, South Korea, Brazil, Spain, and Poland. Results A real-time loop-mediated isothermal amplification (LAMP) assay was developed for rapid detection of porcine circovirus 3 (PCV3). The method had a detection limit of 1 × 101 copies/μL with no cross-reactions with classical swine fever virus (CSFV) C strain, foot-and-mouth disease virus (FMDV), porcine circovirus 2 (PCV2) LG vaccine strain, porcine epidemic diarrhoea virus (PEDV), porcine respiratory and reproductive syndrome virus (PRRSV), or pseudorabies virus (PRV). The PCV3 positive detection rate of 203 clinical samples for the real-time LAMP assay was 89.66% (182/203). Conclusions The real-time LAMP assay is highly sensitive, and specific for use in epidemiological investigations of PCV3.