In-situ, time resolved monitoring of uranium in BFS:OPC grout. Part 1: Corrosion in water vapour

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • Contributors:
      Interface Analysis Centre; University of Bristol [Bristol]; European Synchrotron Radiation Facility (ESRF); School of Metallurgy and Materials; University of Birmingham [Birmingham]
    • بيانات النشر:
      Nature Publishing Group, 2017.
    • الموضوع:
      2017
    • نبذة مختصرة :
      Uranium encapsulated in grout was exposed to water vapour for extended periods of time. Through synchrotron x-ray powder diffraction and tomography measurements, uranium dioxide was determined the dominant corrosion product over a 50-week time period. The oxide growth rate initiated rapidly, with rates comparable to the U + H2O reaction. Over time, the reaction rate decreased and eventually plateaued to a rate similar to the U + H2O + O2 reaction. This behaviour was not attributed to oxygen ingress, but instead the decreasing permeability of the grout, limiting oxidising species access to the metal surface.