Comparison of the Modified Centers for Disease Control and Prevention 2019-Novel Coronavirus Real-Time RT-PCR Method for Detection of Infectious and Heat-Inactivated Virus on Stainless Steel

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • بيانات النشر:
      Oxford University Press (OUP), 2021.
    • الموضوع:
      2021
    • نبذة مختصرة :
      Background Infectious Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2) was used in the validation of methods for detection of SARS-CoV-2 on stainless-steel surfaces in the AOAC Research Institute Emergency Response Validation project. Handling infectious virus requires Biosafety Level (BSL)-3 facilities. Objective To compare the recovery and detection of infectious and heat-inactivated (HI; 65°C for 30 min) SARS-CoV-2 from stainless steel by the modified US Centers for Disease Control and Prevention (CDC) 2019-Novel Coronavirus (2019-nCoV) Real Time Reverse Transcription Polymerase Chain Reaction (RT-PCR) Diagnostic Panel. Method Viral stocks were diluted in viral transport medium (VTM) and deposited onto stainless-steel test areas at 2 × 103 and 2 × 104 genomic copies for low and high, respectively. Test areas were sampled and aliquots of the resulting test solutions analyzed by RT-qPCR according to the CDC method. Results were analyzed by probability of detection (POD) statistics. Results The low level, where fractional positive results (25–75%) are expected, yielded PODI = 0.80 (0.58, 0.92) for the infectious virus and PODHI = 0.15 (0.05, 0.36) for the HI virus. The bias, dPODHI = −0.65 (−0.80, −0.35), demonstrated a statistical difference between infectious and HI virus detection. No difference was observed at the high inoculation level. Conclusions Despite the statistical difference observed, the use of the HI virus is a viable alternative for matrix extension studies using a method comparison study design. Highlights: The use of HI SARS-CoV-2 can mitigate the need for a BSL-3 facility for matrix extension validation of alternative methods in SARS-CoV-2 studies. Highlights The use of HI SARS-CoV-2 can mitigate the need for a BSL-3 facility for matrix extension validation of alternative methods in SARS-CoV-2 studies.
    • ISSN:
      1944-7922
      1060-3271
    • Rights:
      OPEN
    • الرقم المعرف:
      edsair.doi.dedup.....570349f7ae73ff5b5e58de2688fd8081