PRESSURE DROP IN DOWNWARD FLOW OF CONDENSING STEAM OVER A HORIZONTAL BUNDLE OF SQUARE PITCHED TUBES

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • بيانات النشر:
      Informa UK Limited, 2000.
    • الموضوع:
      2000
    • نبذة مختصرة :
      Pressure drop measurements in a 15-row steam condenser configured with in-line tubes, p/D < 1.33, are described. Pressures from 50 to 100 mb and Remax in the range 1,000-18,000 were imposed. It is shown that pressure loss coefficients for the bundle and for two-row pairs were lower than predictions for equivalent single-phase tests except near the bottom of the bundle. There was some evidence that increase in suction parameter increased this effect in the top rows. Taken together with previous investigations [3, 4], a falling trend of suction effect is evident the more closely packed the tubes are. The discrepancy between these findings and the results of simulation experiments [7] is noted.