Comparison of Plastic vs. Glass Evacuated Serum-Separator (SSTTM) Blood-Drawing Tubes for Common Clinical Chemistry Determinations

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • بيانات النشر:
      Oxford University Press (OUP), 1992.
    • الموضوع:
      1992
    • نبذة مختصرة :
      We evaluated a plastic evacuated blood-drawing tube containing an integral serum-separating barrier gel, by direct comparison with a glass counterpart. The plastic tube demonstrated no differences when compared for common clinical chemistry analytes with multiple types of instruments and systems. A total of 260 such different combinations were studied with emphasis on tests sensitive to drawing and handling indexes such as lactate dehydrogenase and potassium. A total of six separate blood drawings were tested with no significant differences noted in these tests. The total study included subjective evaluations of the plastic tube's use as a blood-drawing device and objective studies based on quantitative test results from normal and hospitalized patients and use of the primary sampling tubes (both plastic and glass) for 48-h storage.
    • ISSN:
      1530-8561
      0009-9147
    • الرقم المعرف:
      10.1093/clinchem/38.8.1474
    • Rights:
      OPEN
    • الرقم المعرف:
      edsair.doi...........6044ed80d20c69a42bcd4fee139bff09