UV-C disinfection of ultrasound probes: Challenges of uneven irradiance on complex surfaces.

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • المصدر:
      Publisher: Public Library of Science Country of Publication: United States NLM ID: 101285081 Publication Model: eCollection Cited Medium: Internet ISSN: 1932-6203 (Electronic) Linking ISSN: 19326203 NLM ISO Abbreviation: PLoS One Subsets: MEDLINE
    • بيانات النشر:
      Original Publication: San Francisco, CA : Public Library of Science
    • الموضوع:
    • نبذة مختصرة :
      Medical devices that contact non-intact skin or mucous membranes are considered semi-critical devices and must undergo high-level disinfection (HLD) before use. Studies have identified several potential limitations of UV-C for HLD of semi-critical medical devices, including a lack of data demonstrating that UV-C irradiance can be uniformly applied to complex surfaces that contain grooves, notches and imperfections. This study focused on ultrasound probes as commonly used medical devices to show the distribution of irradiance on these surfaces. An endocavity bi-plane probe and curved array surface probe with typical surface topology were 3D scanned and modelled and an array of UV-C light-emitting diodes (LEDs) irradiating the probe surfaces was simulated (simulated wavelength: 275nm [peak], power output: 50mW). The simulated chamber wall material was equivalent to highly reflective polished aluminum with a defined reflectance of 79% at 275nm. To calculate the cycle time required to achieve HLD on probe surfaces, a minimum effective dosage of 1500mJ/cm2 based on published research was used. The simulated irradiance distribution showed a large difference between the points of highest and lowest irradiance (maximum/minimum ratio: 14.70 for the surface probe and 12.74 for the endocavity probe). In addition, the presence of shadowing effects adjacent to notches or grooves was evident. By applying an effective UV-C dose from the literature, cycle times of up to 25 minutes would be required to achieve HLD in the minimally irradiated areas of the probes used in the simulation. These findings highlight the need to demonstrate the efficacy of UV-C radiation against worst case organisms in the areas of lowest irradiance on medical devices to provide assurance these devices are reliably high level disinfected.
      Competing Interests: LY, LC, MB, LYT, GS and JB are employees of Nanosonics Ltd. LYT, GS and JB hold stock in Nanosonics Ltd. All authors are employed by a commercial company: Nanosonics Ltd. This does not alter our adherence to PLOS ONE policies on sharing data and materials.
      (Copyright: © 2024 Yeoh et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.)
    • References:
      J Res Natl Inst Stand Technol. 2021 Aug 20;126:126021. (PMID: 39081635)
      Environ Sci Technol. 2018 Jan 2;52(1):223-229. (PMID: 29261289)
      Viruses. 2021 Mar 31;13(4):. (PMID: 33807470)
      Infect Dis Clin North Am. 2016 Sep;30(3):609-37. (PMID: 27515140)
      PLoS One. 2024 Feb 23;19(2):e0298449. (PMID: 38394312)
      Antimicrob Resist Infect Control. 2023 Jul 4;12(1):63. (PMID: 37403134)
      Microorganisms. 2023 Feb 02;11(2):. (PMID: 36838351)
      Water Res. 2016 May 1;94:341-349. (PMID: 26971809)
      J Hosp Infect. 2023 Feb;132:85-92. (PMID: 36565930)
      J Res Natl Inst Stand Technol. 2021 Aug 20;126:126017. (PMID: 38469450)
      J Photochem Photobiol B. 1999 Mar;49(1):71-80. (PMID: 10365447)
      Lett Appl Microbiol. 2022 Oct;75(4):933-941. (PMID: 35704393)
      Water Sci Technol. 2001;43(12):171-4. (PMID: 11464748)
      Ultrasound Obstet Gynecol. 2022 Jul;60(1):132-138. (PMID: 34919771)
      J Microbiol Methods. 2022 Sep;200:106541. (PMID: 35870538)
      Burns. 2020 Jun;46(4):842-849. (PMID: 31676249)
      J Ultrasound Med. 2011 Jun;30(6):785-8. (PMID: 21632992)
      Sci Rep. 2022 Aug 2;12(1):13260. (PMID: 35918389)
      Materials (Basel). 2021 Apr 29;14(9):. (PMID: 33946929)
      Environ Sci Technol. 2014;48(1):591-8. (PMID: 24266597)
      J Aerosol Sci. 2022 Aug;164:106003. (PMID: 35496770)
      J Clin Med. 2019 Oct 24;8(11):. (PMID: 31653074)
      Biophys J. 1965 May;5(3):257-73. (PMID: 19431332)
    • الموضوع:
      Date Created: 20241030 Date Completed: 20241030 Latest Revision: 20241101
    • الموضوع:
      20241101
    • الرقم المعرف:
      PMC11524522
    • الرقم المعرف:
      10.1371/journal.pone.0312931
    • الرقم المعرف:
      39476107