Item request has been placed!
×
Item request cannot be made.
×
Processing Request
The influence of contrast media on calcium-based imaging of the spine in dual-layer CT.
Item request has been placed!
×
Item request cannot be made.
×
Processing Request
- معلومة اضافية
- المصدر:
Publisher: Nature Publishing Group Country of Publication: England NLM ID: 101563288 Publication Model: Electronic Cited Medium: Internet ISSN: 2045-2322 (Electronic) Linking ISSN: 20452322 NLM ISO Abbreviation: Sci Rep Subsets: MEDLINE
- بيانات النشر:
Original Publication: London : Nature Publishing Group, copyright 2011-
- الموضوع:
- نبذة مختصرة :
This study aimed to evaluate the impact of contrast media application on CT attenuation of the bone using a novel calcium-only imaging technique (VCa) from dual-layer spectral detector CT (DLCT), which enables CT-based bone mineral density measurement unimpeded by soft tissue components. For this, true non-contrast (TNC) and venous phase images (VP) of n = 97 patients were acquired. CT attenuation of the first lumbar vertebra (L1) was measured in TNC-VCa, VP-VCa, and in virtual non-contrast images (VNC). CT attenuation was significantly higher in VP-VCa than in TNC-VCa (p < 0.001), although regression analyses revealed a strong linear association between these measures (R 2 = 0.84). A statistical model for the prediction of TNC-VCa CT attenuation was established (TNC-VCa[HU] = - 6.81 + 0.87 × VP-VCa[HU]-0.55 × body weight[kg]) and yielded good agreement between observed and predicted values. Furthermore, a L1 CT attenuation threshold of 293 HU in VP-VCa showed a sensitivity of 90% and a specificity of 96% for detecting osteoporosis. The application of contrast media leads to an overestimation of L1 CT attenuation in VCa. However, CT attenuation values from VP-VCa can be used within CT-based opportunistic osteoporosis screening eighter by applying a separate threshold of 293 HU or by converting measured data to TNC-VCa CT attenuation with the given regression equation.
(© 2024. The Author(s).)
- References:
J Gen Intern Med. 2007 Mar;22(3):346-51. (PMID: 17356966)
AJR Am J Roentgenol. 2017 Jan;208(1):165-170. (PMID: 27762605)
Eur J Radiol. 2024 Jul 6;178:111606. (PMID: 39018645)
Med Phys. 2016 Jul;43(7):4174. (PMID: 27370137)
J Bone Miner Res. 2012 Nov;27(11):2338-43. (PMID: 22692725)
Abdom Radiol (NY). 2017 Sep;42(9):2376-2386. (PMID: 28386693)
Eur J Radiol. 2009 Sep;71(3):415-24. (PMID: 19682815)
Rofo. 2017 Jun;189(6):537-543. (PMID: 28445910)
Eur Radiol. 2015 Feb;25(2):283-9. (PMID: 25187384)
Lancet. 2019 Jan 26;393(10169):364-376. (PMID: 30696576)
Calcif Tissue Int. 1992 Jun;50(6):507-10. (PMID: 1525705)
Radiology. 2012 Apr;263(1):3-17. (PMID: 22438439)
Bone. 2018 Jul;112:145-152. (PMID: 29704696)
Dtsch Arztebl Int. 2013 Jan;110(4):52-7. (PMID: 23413388)
PLoS Med. 2007 Oct 16;4(10):e297. (PMID: 17941715)
J Gen Intern Med. 2004 Jul;19(7):783-90. (PMID: 15209594)
Eur J Radiol. 2019 Dec;121:108740. (PMID: 31733433)
J Comput Assist Tomogr. 1982 Jun;6(3):601-7. (PMID: 7096705)
J Appl Clin Med Phys. 2013 Nov 04;14(6):4417. (PMID: 24257284)
J Bone Joint Surg Am. 2017 Sep 20;99(18):1580-1590. (PMID: 28926388)
Arch Osteoporos. 2013;8:137. (PMID: 24113838)
Osteoporos Int. 2005 Mar;16 Suppl 2:S3-7. (PMID: 15365697)
Chest. 2008 Dec;134(6):1244-1249. (PMID: 18641115)
Eur J Radiol. 2015 Nov;84(11):2269-74. (PMID: 26283192)
Stat Med. 2000 May 15;19(9):1141-64. (PMID: 10797513)
J Biomech Eng. 2015 Nov;137(11):114502. (PMID: 26355694)
Bone. 2020 Jan;130:115100. (PMID: 31678491)
J Bone Miner Metab. 2017 Jul;35(4):428-436. (PMID: 27942979)
Br J Radiol. 2018 Apr;91(1084):20170395. (PMID: 29308913)
Ann Intern Med. 2013 Apr 16;158(8):588-95. (PMID: 23588747)
AJR Am J Roentgenol. 2015 Jun;204(6):1234-41. (PMID: 26001233)
- Contributed Indexing:
Keywords: Computed tomography; Contrast media; Dual-layer spectral CT; Virtual non-calcium
- الرقم المعرف:
0 (Contrast Media)
SY7Q814VUP (Calcium)
- الموضوع:
Date Created: 20240814 Date Completed: 20240814 Latest Revision: 20240817
- الموضوع:
20240817
- الرقم المعرف:
PMC11324893
- الرقم المعرف:
10.1038/s41598-024-69743-3
- الرقم المعرف:
39143146
No Comments.