A New Model of Air-Oxygen Blender for Mechanical Ventilators Using Dynamic Pressure Sensors.
Item request has been placed!
×
Item request cannot be made.
×

Processing Request
- معلومة اضافية
- المصدر:
Publisher: MDPI Country of Publication: Switzerland NLM ID: 101204366 Publication Model: Electronic Cited Medium: Internet ISSN: 1424-8220 (Electronic) Linking ISSN: 14248220 NLM ISO Abbreviation: Sensors (Basel) Subsets: MEDLINE
- بيانات النشر:
Original Publication: Basel, Switzerland : MDPI, c2000-
- الموضوع:
- نبذة مختصرة :
Respiratory diseases are among the leading causes of death globally, with the COVID-19 pandemic serving as a prominent example. Issues such as infections affect a large population and, depending on the mode of transmission, can rapidly spread worldwide, impacting thousands of individuals. These diseases manifest in mild and severe forms, with severely affected patients requiring ventilatory support. The air-oxygen blender is a critical component of mechanical ventilators, responsible for mixing air and oxygen in precise proportions to ensure a constant supply. The most commonly used version of this equipment is the analog model, which faces several challenges. These include a lack of precision in adjustments and the inspiratory fraction of oxygen, as well as gas wastage from cylinders as pressure decreases. The research proposes a blender model utilizing only dynamic pressure sensors to calculate oxygen saturation, based on Bernoulli's equation. The model underwent validation through simulation, revealing a linear relationship between pressures and oxygen saturation up to a mixture outlet pressure of 500 cmH 2 O. Beyond this value, the relationship begins to exhibit non-linearities. However, these non-linearities can be mitigated through a calibration algorithm that adjusts the mathematical model. This research represents a relevant advancement in the field, addressing the scarcity of work focused on this essential equipment crucial for saving lives.
- References:
Int J Environ Res Public Health. 2023 Jan 18;20(3):. (PMID: 36767152)
Intensive Care Med. 2021 Mar;47(3):282-291. (PMID: 33616696)
Intensive Crit Care Nurs. 2023 Feb;74:103344. (PMID: 36357234)
Mayo Clin Proc. 2017 Sep;92(9):1382-1400. (PMID: 28870355)
Expert Rev Respir Med. 2010 Dec;4(6):809-19. (PMID: 21128755)
Annu Int Conf IEEE Eng Med Biol Soc. 2020 Jul;2020:5154-5157. (PMID: 33019146)
EClinicalMedicine. 2021 Feb 12;32:100757. (PMID: 33659889)
Front Pediatr. 2022 Sep 12;10:981821. (PMID: 36186642)
Am J Respir Crit Care Med. 2021 Jan 1;203(1):54-66. (PMID: 33119402)
Am J Respir Crit Care Med. 2004 Nov 15;170(10):1095-100. (PMID: 15347564)
Emerg Med Clin North Am. 2008 Aug;26(3):849-62, x. (PMID: 18655948)
Sensors (Basel). 2022 Mar 11;22(6):. (PMID: 35336353)
Pulmonology. 2023 Oct 28;:. (PMID: 37903684)
- Grant Information:
Grant No. 306607/2023-9 National Council for Scientific and Technological Development
- Contributed Indexing:
Keywords: FIO2; blender; mechanical ventilator; simulation
- الرقم المعرف:
S88TT14065 (Oxygen)
- الموضوع:
Date Created: 20240313 Date Completed: 20240314 Latest Revision: 20240315
- الموضوع:
20250114
- الرقم المعرف:
PMC10933838
- الرقم المعرف:
10.3390/s24051481
- الرقم المعرف:
38475015
No Comments.