Improved U-Net Model to Estimate Cardiac Output Based on Photoplethysmography and Arterial Pressure Waveform.

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • المؤلفون: Xu X;Xu X; Tang Q; Tang Q; Chen Z; Chen Z
  • المصدر:
    Sensors (Basel, Switzerland) [Sensors (Basel)] 2023 Nov 09; Vol. 23 (22). Date of Electronic Publication: 2023 Nov 09.
  • نوع النشر :
    Journal Article
  • اللغة:
    English
  • معلومة اضافية
    • المصدر:
      Publisher: MDPI Country of Publication: Switzerland NLM ID: 101204366 Publication Model: Electronic Cited Medium: Internet ISSN: 1424-8220 (Electronic) Linking ISSN: 14248220 NLM ISO Abbreviation: Sensors (Basel) Subsets: MEDLINE
    • بيانات النشر:
      Original Publication: Basel, Switzerland : MDPI, c2000-
    • الموضوع:
    • نبذة مختصرة :
      We aimed to estimate cardiac output (CO) from photoplethysmography (PPG) and the arterial pressure waveform (ART) using a deep learning approach, which is minimally invasive, does not require patient demographic information, and is operator-independent, eliminating the need to artificially extract a feature of the waveform by implementing a traditional formula. We aimed to present an alternative to measuring cardiac output with greater accuracy for a wider range of patients. Using a publicly available dataset, we selected 543 eligible patients and divided them into test and training sets after preprocessing. The data consisted of PPG and ART waveforms containing 2048 points with the corresponding CO. We achieved an improvement based on the U-Net modeling framework and built a two-channel deep learning model to automatically extract the waveform features to estimate the CO in the dataset as the reference, acquired using the EV1000, a commercially available instrument. The model demonstrated strong consistency with the reference values on the test dataset. The mean CO was 5.01 ± 1.60 L/min and 4.98 ± 1.59 L/min for the reference value and the predicted value, respectively. The average bias was -0.04 L/min with a -1.025 and 0.944 L/min 95% limit of agreement (LOA). The bias was 0.79% with a 95% LOA between -20.4% and 18.8% when calculating the percentage of the difference from the reference. The normalized root-mean-squared error (RMSNE) was 10.0%. The Pearson correlation coefficient (r) was 0.951. The percentage error (PE) was 19.5%, being below 30%. These results surpassed the performance of traditional formula-based calculation methods, meeting clinical acceptability standards. We propose a dual-channel, improved U-Net deep learning model for estimating cardiac output, demonstrating excellent and consistent results. This method offers a superior reference method for assessing cardiac output in cases where it is unnecessary to employ specialized cardiac output measurement devices or when patients are not suitable for pulmonary-artery-catheter-based measurements, providing a viable alternative solution.
    • References:
      Lancet. 1986 Feb 8;1(8476):307-10. (PMID: 2868172)
      Sci Rep. 2020 Oct 19;10(1):17684. (PMID: 33077774)
      Int J Cardiol. 2013 Oct 9;168(4):4411-2. (PMID: 23714596)
      Sci Data. 2022 Jun 8;9(1):279. (PMID: 35676300)
      Biomed Mater Eng. 2014;24(6):2909-18. (PMID: 25226997)
      Comput Cardiol. 2009 Jan 1;2009(36):197-200. (PMID: 20740055)
      Sensors (Basel). 2021 Mar 07;21(5):. (PMID: 33800106)
      Br J Anaesth. 2015 Apr;114(4):562-75. (PMID: 25596280)
      J Clin Monit Comput. 1999 Feb;15(2):85-91. (PMID: 12578081)
      Lancet. 2003 Nov 29;362(9398):1839-46. (PMID: 14654324)
      Ann Intensive Care. 2013 Nov 28;3(1):38. (PMID: 24286266)
      Stat Methods Med Res. 1999 Jun;8(2):135-60. (PMID: 10501650)
      Lancet. 2019 Feb 2;393(10170):401. (PMID: 30722955)
      Anesthesiology. 2010 Nov;113(5):1220-35. (PMID: 20881596)
      Crit Care. 2009;13(1):201. (PMID: 19183431)
      Crit Care. 2003 Apr;7(2):114-6. (PMID: 12720554)
      Anaesthesiol Intensive Ther. 2012 Oct-Dec;44(4):188-99. (PMID: 23348485)
      Biosensors (Basel). 2022 Aug 18;12(8):. (PMID: 36005051)
      Biomed Eng Online. 2013 Mar 04;12:19. (PMID: 23452705)
      Sensors (Basel). 2022 Jan 25;22(3):. (PMID: 35161664)
      PLoS One. 2016 Oct 13;11(10):e0164521. (PMID: 27736921)
      J Clin Med. 2019 Sep 09;8(9):. (PMID: 31505848)
      Crit Care Explor. 2022 Feb 01;4(2):e0624. (PMID: 35128457)
      Science. 1909 Jul 2;30(757):23-5. (PMID: 17838275)
      Curr Cardiol Rev. 2012 Feb;8(1):14-25. (PMID: 22845812)
      Physiol Meas. 2010 May;31(5):715-26. (PMID: 20395650)
      IEEE Trans Biomed Eng. 2005 Nov;52(11):1889-901. (PMID: 16285393)
      Annu Int Conf IEEE Eng Med Biol Soc. 2009;2009:1746-9. (PMID: 19963762)
      Anesthesiology. 2011 May;114(5):1245; author reply 1245-6. (PMID: 21521974)
    • Contributed Indexing:
      Keywords: U-Net; arterial pressure waveform; cardiac output; deep learning model; minimally invasive; photoplethysmography
    • الموضوع:
      Date Created: 20231125 Date Completed: 20231127 Latest Revision: 20231127
    • الموضوع:
      20231128
    • الرقم المعرف:
      PMC10675453
    • الرقم المعرف:
      10.3390/s23229057
    • الرقم المعرف:
      38005445