Real-Time Measurements of Indoor-Outdoor Exchange of Gaseous and Particulate Atmospheric Pollutants in an Urban Area.

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • المصدر:
      Publisher: MDPI Country of Publication: Switzerland NLM ID: 101238455 Publication Model: Electronic Cited Medium: Internet ISSN: 1660-4601 (Electronic) Linking ISSN: 16604601 NLM ISO Abbreviation: Int J Environ Res Public Health Subsets: MEDLINE
    • بيانات النشر:
      Original Publication: Basel : MDPI, c2004-
    • الموضوع:
    • نبذة مختصرة :
      Air pollution is one of the greatest environmental risks to health, causing millions of deaths and deleterious health effects worldwide, especially in urban areas where citizens are exposed to high ambient levels of pollutants, also influencing indoor air quality (IAQ). Many sources of indoor air are fairly obvious and well known, but the contribution of outside sources to indoor air still leads to significant uncertainties, in particular the influence that environmental variables have on outdoor/indoor pollutant exchange mechanisms. This is a critical aspect to consider in IAQ studies. In this respect, an experimental study was performed at a public site such as a university classroom during a non-academic period in Madrid city. This includes two field campaigns, in summer (2021) and winter (2020), where instruments for measuring gases and particle air pollutants simultaneously measured outdoor and indoor real-time concentrations. This study aimed to investigate the dynamic variations in the indoor/outdoor (I/O) ratios in terms of ambient outdoor conditions (meteorology, turbulence and air quality) and indoor features (human presence or natural ventilation). The results show that the I/O ratio is pollutant-dependent. In this sense, the infiltration capacity is higher for gaseous compounds, and in the case of particles, it depends on the particle size, with a higher infiltration capacity for smaller particles (2.5 ). Additionally, under specific situations of high atmospheric stability, the concentrations of gases derived from traffic tend to accumulate in the room, keeping the background concentrations. These concentrations decreased when room ventilation was produced simultaneously with well-ventilated (high wind speed) external conditions. This suggests that the meteorology and turbulence parameters played a key role in influencing indoor ambient pollution conditions by enhancing the dispersion or accumulation of pollutants. The obtained results highlight the high number of variables involved in the outdoor/indoor exchange of air pollutants and, consequently, how complex its study is. Thus, the knowledge of these factors is critical for understanding the behavior of indoor pollutants and controlling human exposure in indoor environments.
    • References:
      Indoor Air. 2008 Dec;18(6):454-63. (PMID: 18823343)
      Int J Environ Res Public Health. 2021 Mar 22;18(6):. (PMID: 33810001)
      Sci Total Environ. 2018 Sep 1;635:1561-1573. (PMID: 29605235)
      Environ Int. 2019 Sep;130:104887. (PMID: 31195224)
      J Air Waste Manag Assoc. 2013 Oct;63(10):1113-29. (PMID: 24282964)
      J Expo Anal Environ Epidemiol. 2000 Sep-Oct;10(5):478-87. (PMID: 11051537)
      Sci Total Environ. 2007 Dec 15;388(1-3):128-36. (PMID: 17888492)
      Environ Res. 2015 Oct;142:495-510. (PMID: 26277386)
      Sci Total Environ. 2017 Sep 1;593-594:543-551. (PMID: 28360004)
      Int J Environ Res Public Health. 2020 Apr 03;17(7):. (PMID: 32260094)
      Sci Total Environ. 2023 Mar 10;863:160973. (PMID: 36539092)
      Environ Int. 2014 Aug;69:200-12. (PMID: 24875803)
      Am Ind Hyg Assoc J. 1976 Oct;37(10):570-7. (PMID: 983946)
      Indoor Air. 2005 Feb;15(1):2-12. (PMID: 15660564)
      Sci Total Environ. 2014 Aug 15;490:757-65. (PMID: 24907610)
      Environ Res. 2019 Mar;170:83-91. (PMID: 30576993)
      Environ Sci Pollut Res Int. 2021 Jul;28(28):37727-37740. (PMID: 33723779)
      Sci Rep. 2017 Apr 11;7:45956. (PMID: 28397785)
    • Contributed Indexing:
      Keywords: gaseous and particulate pollutants; indoor activities; indoor air quality (IAQ); real-time I/O measurements; urban air pollutants