Factors related to the skin thickness of cardiovascular implantable electronic device pockets.

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • المصدر:
      Publisher: Blackwell Country of Publication: United States NLM ID: 9010756 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1540-8167 (Electronic) Linking ISSN: 10453873 NLM ISO Abbreviation: J Cardiovasc Electrophysiol Subsets: MEDLINE
    • بيانات النشر:
      Publication: Malden, MA : Blackwell
      Original Publication: Mt. Kisco, N.Y. : Futura Pub., c1990-
    • الموضوع:
    • نبذة مختصرة :
      Introduction: The skin overlying cardiovascular implantable electronic devices (CIEDs) sometimes becomes very thin after implantations, which could cause a device erosion. The factors related to the skin thickness of device pockets have not been elucidated. This study aimed to evaluate the skin thickness of CIED pockets and search for the factors associated with the thickness.
      Methods: Seventeen skin thickness points around the CIED pocket were measured through ultrasonography in each patient.
      Results: A total of 101 patients (76 ± 11 years, 26 female) were enrolled. The median duration from the implantation to the examination was 95 months (quartile: 52.5-147.5). The median skin thickness overlying the device was 4.1 mm (3.3-5.9). Patients with heart failure and malignancy had thinner skin overlying the CIED than those without. A significant correlation existed between skin thickness and body mass index (BMI), hemoglobin, serum creatinine, estimated glomerular filtration rate (eGFR), and left ventricular ejection fraction. In contrast, age, gender, and device size did not exhibit a significant correlation with skin thickness. A multivariate logistic regression analysis revealed that chronic heart failure and a decrease in the eGFR and BMI were independent predictive factors of "very thin (≦3.3 mm)" skin of the CIED pocket late after an implantation.
      Conclusion: Aside from a low BMI, the comorbidities (low hemoglobin, heart failure, and renal dysfunction) had a stronger impact on the skin thickness overlying the device than the device size. A careful observation of the device pocket should be performed in patients with those risk factors.
      (© 2022 Wiley Periodicals LLC.)
    • Comments:
      Comment in: J Cardiovasc Electrophysiol. 2022 Aug;33(8):1857-1862. (PMID: 35761750)
    • References:
      Mond HG, Proclemer A. The 11th world survey of cardiac pacing and implantable cardioverter-defibrillators: calendar year 2009-a World Society of Arrhythmia's project. Pacing Clin Electrophysiol. 2011;34:1013-1027.
      Raatikainen MJP, Arnar DO, Merkely B, et al. A decade of information on the use of cardiac implantable electronic devices and interventional electrophysiological procedures in the European Society of Cardiology Countries: 2017 Report from the European Heart Rhythm Association. Europace. 2017;19:ii1-ii90.
      Blomstrom-Lundqvist C, Traykov V, Erba PA, et al. European Heart Rhythm Association (EHRA) international consensus document on how to prevent, diagnose, and treat cardiac implantable electronic device infections-endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), the Latin American Heart Rhythm Society (LAHRS), International Society for Cardiovascular Infectious Diseases (ISCVID) and the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS). Europace. 2020;22:515-549.
      Chua JD, Wilkoff BL, Lee I, Juratli N, Longworth DL, Gordon SM. Diagnosis and management of infections involving implantable electrophysiologic cardiac devices. Ann Intern Med. 2000;133:604-608.
      Ludescher B, Rommel M, Willmer T, Fritsche A, Schick F, Machann J. Subcutaneous adipose tissue thickness in adults - correlation with BMI and recommendations for pen needle lengths for subcutaneous self-injection. Clin Endocrinol. 2011;75:786-790.
      Laurent A, Mistretta F, Bottigioli D, et al. Echographic measurement of skin thickness in adults by high frequency ultrasound to assess the appropriate microneedle length for intradermal delivery of vaccines. Vaccine. 2007;25:6423-6430.
      Lopez A, Cacoub P, Macdougall IC, Peyrin-Biroulet L. Iron deficiency anaemia. Lancet. 2016;387:907-916.
      Pandey A, Kitzman D, Reeves G. Frailty is intertwined with heart failure: mechanisms, prevalence, prognosis, assessment, and management. JACC Heart Fail. 2019;7:1001-1011.
      Moorthi RN, Avin KG. Clinical relevance of sarcopenia in chronic kidney disease. Curr Opin Nephrol Hypertens. 2017;26:219-228.
      Chambers ES, Vukmanovic-Stejic M. Skin barrier immunity and ageing. Immunology. 2020;160:116-125.
      Iizaka S. Frailty and body mass index are associated with biophysical properties of the skin in community-dwelling older adults. J Tissue Viability. 2018;27:141-145.
      Perry L, Karp F, Hauch K, Ratner BD. Explanted pacemakers: observations of the long-term foreign body response. Interface. 2007;4:13-21.
      Steckiewicz R, Swieton EB, Kolodzinska A, Bogdanska M, Fus L, Solarz P. Morphometric parameters of cardiac implantable electronic device (CIED) pocket walls observed on device replacement. Folia Morphol. 2017;76:675-681.
      Deegan D, Riebman J. Small intestinal submucosa extracellular matrix envelopes secure cardiovascular implantable devices and promote healthy tissue remodeling. Authorea Preprints. 2021. doi:10.22541/au.162740708.87184630/v1.
      Pothineni NVK, Kumareswaran R, Schaller RD. Pacemaker pocket stabilization utilizing a novel envelope and a three-point anchoring technique. Cureus. 2021;13:e13108.
      Van Mulder TJ, de Koeijer M, Theeten H, et al. High frequency ultrasound to assess skin thickness in healthy adults. Vaccine. 2017;35:1810-1815.
    • Contributed Indexing:
      Keywords: cardiovascular implantable electronic devices; device erosion; device infection; device pocket; skin thickness
    • الموضوع:
      Date Created: 20220628 Date Completed: 20220823 Latest Revision: 20220923
    • الموضوع:
      20240628
    • الرقم المعرف:
      10.1111/jce.15613
    • الرقم المعرف:
      35761749