Item request has been placed!
×
Item request cannot be made.
×
Processing Request
Standardized artificially created stable pertrochanteric femur fractures present more homogenous results compared to osteotomies for orthopaedic implant testing.
Item request has been placed!
×
Item request cannot be made.
×
Processing Request
- معلومة اضافية
- المصدر:
Publisher: BioMed Central Country of Publication: England NLM ID: 100968565 Publication Model: Electronic Cited Medium: Internet ISSN: 1471-2474 (Electronic) Linking ISSN: 14712474 NLM ISO Abbreviation: BMC Musculoskelet Disord Subsets: MEDLINE
- بيانات النشر:
Original Publication: London : BioMed Central, [2000-
- الموضوع:
- نبذة مختصرة :
Background: With regard to biomechanical testing of orthopaedic implants, there is no consensus on whether artificial creation of standardized bone fractures or their simulation by means of osteotomies result in more realistic outcomes. Therefore, the aim of this study was to artificially create and analyze in an appropriate setting the biomechanical behavior of standardized stable pertrochanteric fractures versus their simulation via osteotomizing.
Methods: Eight pairs of fresh-frozen human cadaveric femora aged 72.7 ± 14.9 years (range 48-89 years) were assigned in paired fashion to two study groups. In Group 1, stable pertrochanteric fractures AO/OTA 31-A1 were artificially created via constant force application on the anterior cortex of the femur through a blunt guillotine blade. The same fracture type was simulated in Group 2 by means of osteotomies. All femora were implanted with a dynamic hip screw and biomechanically tested in 20° adduction under progressively increasing physiologic cyclic axial loading at 2 Hz, starting at 500 N and increasing at a rate of 0.1 N/cycle. Femoral head fragment movements with respect to the shaft were monitored by means of optical motion tracking.
Results: Cycles/failure load at 15° varus deformation, 10 mm leg shortening and 15° femoral head rotation around neck axis were 11324 ± 848/1632.4 ± 584.8 N, 11052 ± 1573/1605.2 ± 657.3 N and 11849 ± 1120/1684.9 ± 612.0 N in Group 1, and 10971 ± 2019/1597.1 ± 701.9 N, 10681 ± 1868/1568.1 ± 686.8 N and 10017 ± 4081/1501.7 ± 908.1 N in Group 2, respectively, with no significant differences between the two groups, p ≥ 0.233.
Conclusion: From a biomechanical perspective, by resulting in more consistent outcomes under dynamic loading, standardized artificial stable pertrochanteric femur fracture creation may be more suitable for orthopaedic implant testing compared to osteotomizing the bone.
- References:
J Orthop Trauma. 1993;7(3):261-9. (PMID: 8326432)
Injury. 2005 Jul;36(7):858-61. (PMID: 15949488)
Unfallchirurg. 2007 May;110(5):425-32. (PMID: 17361444)
Acta Orthop. 2014 Apr;85(2):177-80. (PMID: 24479620)
N Engl J Med. 2012 Mar 1;366(9):848-55. (PMID: 22332952)
Clin Biomech (Bristol, Avon). 2009 Jan;24(1):59-64. (PMID: 18977058)
J Orthop Trauma. 2018 Jan;32 Suppl 1:S1-S170. (PMID: 29256945)
Injury. 2002 Oct;33(8):713-5. (PMID: 12213423)
J Orthop Res. 1984;2(1):97-101. (PMID: 6491805)
J Biomech. 2014 Jan 22;47(2):536-43. (PMID: 24275435)
Unfallchirurg. 2011 Jun;114(6):491-500. (PMID: 21656037)
J Biomech. 2007;40(13):2837-45. (PMID: 17475269)
JMIR Res Protoc. 2019 Jul 18;8(7):e12845. (PMID: 31322133)
J Orthop Res. 2017 Oct;35(10):2154-2163. (PMID: 28054384)
BMJ Open. 2018 Oct 18;8(10):e021650. (PMID: 30341116)
Injury. 2000 May;31 Suppl 2:S-B37-50. (PMID: 10853760)
J Biomech. 2015 Mar 18;48(5):807-15. (PMID: 25579993)
J Orthop Trauma. 2011 Jun;25(6):340-6. (PMID: 21577069)
Injury. 2017 Feb;48(2):277-284. (PMID: 28040260)
J Orthop Res. 2014 Jan;32(1):31-8. (PMID: 24019186)
J Orthop Trauma. 2000 Jun-Jul;14(5):318-23. (PMID: 10926237)
J Bone Miner Res. 2004 Mar;19(3):379-85. (PMID: 15040825)
J Bone Miner Res. 1992 Dec;7 Suppl 2:S437-44. (PMID: 1485554)
Injury. 1982 Nov;14(3):236-42. (PMID: 7152646)
Bone. 2018 Sep;114:206-214. (PMID: 29909060)
J Biomech. 2001 Jul;34(7):859-71. (PMID: 11410170)
- Contributed Indexing:
Keywords: Fracture biomechanics; Fracture line analysis; Fracture model; Fracture standardization; Osteotomy; Proximal femur fracture; Stable pertrochanteric fracture
- الموضوع:
Date Created: 20210421 Date Completed: 20210514 Latest Revision: 20210514
- الموضوع:
20231215
- الرقم المعرف:
PMC8058974
- الرقم المعرف:
10.1186/s12891-021-04234-4
- الرقم المعرف:
33879133
No Comments.