A prospective, randomised study of the effect of fixation sutures during phacotrabeculectomy on intraocular pressure and incidence of ptosis.
Item request has been placed!
×
Item request cannot be made.
×
Processing Request
- معلومة اضافية
- المصدر:
Publisher: Nature Publishing Group Country of Publication: England NLM ID: 101563288 Publication Model: Electronic Cited Medium: Internet ISSN: 2045-2322 (Electronic) Linking ISSN: 20452322 NLM ISO Abbreviation: Sci Rep Subsets: MEDLINE
- بيانات النشر:
Original Publication: London : Nature Publishing Group, copyright 2011-
- الموضوع:
- نبذة مختصرة :
We investigated the effects of different intraoperative eyeball fixation techniques (superior rectus muscle suture [MS] and traction suture at the corneal limbus [CS]), on intraocular pressure (IOP) and the incidence of ptosis after phacotrabeculectomy. Forty-one eyes with different glaucoma types which qualified for phacotrabeculectomy were included. Twenty-three and eighteen patients were included in the CS and MS groups, respectively. The IOP, best-corrected visual acuity (BCVA), and margin reflex distance were assessed preoperatively and 3, 6, and 12 months post-operatively. Preoperatively, the mean IOPs (± standard deviation) in the CS and MS groups were 23.6 ± 7.3 mmHg and 24.3 ± 6.6 mmHg (p > 0.05), respectively. At 3 and 6 months post-surgery, the mean IOPs were significantly lower in the CS group than in the MS group: 13.9 ± 3.0 mmHg vs. 17.7 ± 3.5 mmHg (p = 0.001), and 13.9 ± 4.9 mmHg vs. 17.2 ± 3.5 mmHg (p = 0.005), respectively (mean difference: 3.9, 95% confidence interval 1.7-6.1). At 12 months, the mean postoperative IOPs were 15.2 ± 3.5 mmHg and 14.9 ± 3.6 mmHg in the CS and MS groups, respectively (p > 0.05). At 6 months, the BCVAs were 0.91 ± 0.15 and 0.71 ± 0.3 (p = 0.029) in the CS and MS groups, respectively; BCVAs were 0.91 ± 0.15 and 0.71 ± 0.3 (p = 0.029) in the CS and MS groups, respectively; the difference was non-significant 12 months post-surgery (0.78 ± 0.32 vs. 0.74 ± 0.30, p = 0.553). Postoperative ptosis was observed in 4 (17%) and zero patients in the CS and MS groups, respectively, but the difference was not statistically significant (p = 0.118). The study was not powered sufficiently to detect statistically significant changes in exploratory endpoints. The study was not powered sufficiently to detect statistically significant differences between groups in exploratory endpoints.
- References:
Semin Ophthalmol. 2014 Jul;29(4):226-35. (PMID: 24654699)
J Glaucoma. 2015 Aug;24(6):417-20. (PMID: 25318575)
J Pediatr. 2015 Nov;167(5):1160-60.e1. (PMID: 26282241)
Br J Ophthalmol. 1989 Apr;73(4):283-5. (PMID: 2713306)
Ophthalmology. 2004 Jan;111(1):97-103. (PMID: 14711719)
Indian J Ophthalmol. 2015 Dec;63(12):895-8. (PMID: 26862093)
Korean J Ophthalmol. 1996 Dec;10(2):97-103. (PMID: 9055538)
Ophthalmic Plast Reconstr Surg. 2018 Sep/Oct;34(5):436-439. (PMID: 29329174)
Curr Eye Res. 2016;41(2):215-21. (PMID: 25803293)
J Ophthalmol. 2015;2015:613280. (PMID: 26576293)
J Glaucoma. 2007 Jan;16(1):14-9. (PMID: 17224744)
Int J Oral Maxillofac Surg. 2012 Jan;41(1):9-16. (PMID: 22057121)
Arch Soc Esp Oftalmol. 2009 Jun;84(6):293-7. (PMID: 19568989)
J Craniofac Surg. 2015 Oct;26(7):e569-71. (PMID: 26468822)
J Glaucoma. 2014 Mar;23(3):190-3. (PMID: 24326967)
Ophthalmology. 1985 Feb;92(2):237-42. (PMID: 3982804)
Surv Ophthalmol. 1987 Nov-Dec;32(3):149-70. (PMID: 3328315)
Am J Ophthalmol. 2014 Feb;157(2):433-440.e3. (PMID: 24210765)
- الموضوع:
Date Created: 20210113 Date Completed: 20210830 Latest Revision: 20210830
- الموضوع:
20221213
- الرقم المعرف:
PMC7804261
- الرقم المعرف:
10.1038/s41598-020-79635-x
- الرقم المعرف:
33436700
No Comments.