Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Evaluation of biomechanically corrected intraocular pressure using Corvis ST and comparison of the Corvis ST, noncontact tonometer, and Goldmann applanation tonometer in patients with glaucoma.

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • المؤلفون: Nakao Y;Nakao Y; Kiuchi Y; Kiuchi Y; Okumichi H; Okumichi H
  • المصدر:
    PloS one [PLoS One] 2020 Sep 23; Vol. 15 (9), pp. e0238395. Date of Electronic Publication: 2020 Sep 23 (Print Publication: 2020).
  • نوع النشر :
    Clinical Trial; Comparative Study; Journal Article
  • اللغة:
    English
  • معلومة اضافية
    • المصدر:
      Publisher: Public Library of Science Country of Publication: United States NLM ID: 101285081 Publication Model: eCollection Cited Medium: Internet ISSN: 1932-6203 (Electronic) Linking ISSN: 19326203 NLM ISO Abbreviation: PLoS One Subsets: MEDLINE
    • بيانات النشر:
      Original Publication: San Francisco, CA : Public Library of Science
    • الموضوع:
    • نبذة مختصرة :
      Purpose: The aim of the study was to investigate the effects of various anatomical structures on intraocular pressure (IOP) measurements obtained by the Corneal Visualization Scheimpflug Technology (Corvis ST), Goldmann applanation tonometer (GAT), and noncontact tonometer (NCT), as well as to assess the interchangeability among the four types of IOP measurement: IOP-GAT, IOP-NCT, IOP-Corvis, and biomechanically corrected IOP (bIOP-Corvis), with a particular focus on bIOP-Corvis.
      Materials and Methods: We included 71 patients with primary open-angle glaucoma and assessed their IOP measurements obtained with the GAT, NCT, and Corvis ST using a repeated measures ANOVA, a paired t-test with Bonferroni correction, stepwise multiple regression analyses and Bland-Altman plots.
      Results: IOP-GAT showed the highest values (13.5 ± 2.1 mmHg [mean ± standard deviation]), followed by IOP-NCT (13.2 ± 2.7 mmHg), IOP-Corvis (10.6 ± 2.8 mmHg), and bIOP-Corvis (10.0 ± 2.3 mmHg). With exceptions of bIOP-Corvis and IOP-GAT, all IOP variations were explained by regression coefficients involving the central corneal thickness. Bland-Altman plots showed a mean difference between IOP-GAT and the other IOP measurements (IOP-Corvis, bIOP-Corvis, and IOP-NCT), which were -2.90, -3.48, and -0.29 mmHg, respectively. The widths of the 95% limits of agreement between all pairs of IOP measurements were greater than 3 mmHg.
      Conclusion: IOP values obtained with the Corvis ST, NCT, and GAT were not interchangeable. The bIOP-Corvis measurement corrected for the ocular structure.
      Competing Interests: The authors have declared that no competing interests exist.
    • References:
      J Cataract Refract Surg. 2001 Nov;27(11):1787-91. (PMID: 11709252)
      Ophthalmic Physiol Opt. 2003 Nov;23(6):503-6. (PMID: 14622352)
      Br J Ophthalmol. 2020 Jan;104(1):121-126. (PMID: 30923134)
      Invest Ophthalmol Vis Sci. 2013 Jan 23;54(1):659-65. (PMID: 23307970)
      Acta Ophthalmol (Copenh). 1975 Mar;53(1):34-43. (PMID: 1172910)
      Klin Monbl Augenheilkd. 1991 Sep;199(3):183-6. (PMID: 1753670)
      J Glaucoma. 2015 Oct-Nov;24(8):568-74. (PMID: 25318572)
      Invest Ophthalmol Vis Sci. 2014 Feb 04;55(2):666-73. (PMID: 24425850)
      J Glaucoma. 2019 Oct;28(10):922-928. (PMID: 31453898)
      J Cataract Refract Surg. 2002 Mar;28(3):504-6. (PMID: 11973098)
      J Glaucoma. 2001 Jun;10(3):220-6. (PMID: 11442187)
      Cont Lens Anterior Eye. 2015 Apr;38(2):94-8. (PMID: 25467287)
      Jpn J Ophthalmol. 2000 Nov 1;44(6):691. (PMID: 11094194)
      Int J Ophthalmol. 2017 Oct 18;10(10):1573-1579. (PMID: 29062778)
      Acta Ophthalmol. 2015 May;93(3):e193-8. (PMID: 25270375)
      J Cataract Refract Surg. 2005 Jan;31(1):156-62. (PMID: 15721708)
      J Glaucoma. 2006 Oct;15(5):364-70. (PMID: 16988597)
      Br J Ophthalmol. 2005 Jul;89(7):851-4. (PMID: 15965165)
      Br J Ophthalmol. 1997 Dec;81(12):1116. (PMID: 9497479)
      Ophthalmic Physiol Opt. 2002 Nov;22(6):560-4. (PMID: 12477021)
      Am J Ophthalmol. 1993 May 15;115(5):592-6. (PMID: 8488910)
      Br J Ophthalmol. 2012 Jun;96(6):806-10. (PMID: 22399691)
      Graefes Arch Clin Exp Ophthalmol. 2011 Mar;249(3):429-34. (PMID: 20981434)
      Am J Ophthalmol. 1973 Aug;76(2):223-4. (PMID: 4725005)
      Clin Ophthalmol. 2011;5:249-58. (PMID: 21468330)
      J Refract Surg. 2016 Aug 1;32(8):550-61. (PMID: 27505316)
      PLoS One. 2017 Jan 17;12(1):e0170206. (PMID: 28095506)
      Int Ophthalmol. 1980 Dec;3(1):31-5. (PMID: 7216628)
      Br J Ophthalmol. 2013 Nov;97(11):1410-4. (PMID: 23969314)
      Arch Ophthalmol. 2002 Oct;120(10):1268-79. (PMID: 12365904)
      Transl Vis Sci Technol. 2019 Jun 24;8(3):48. (PMID: 31275733)
    • Molecular Sequence:
      figshare 10.6084/m9.figshare.11954748
    • الموضوع:
      Date Created: 20200923 Date Completed: 20201026 Latest Revision: 20201026
    • الموضوع:
      20231215
    • الرقم المعرف:
      PMC7510959
    • الرقم المعرف:
      10.1371/journal.pone.0238395
    • الرقم المعرف:
      32966284