Real-Time Monitoring of Blood Pressure Using Digitalized Pulse Arrival Time Calculation Technology for Prompt Detection of Sudden Hypertensive Episodes During Laryngeal Microsurgery: Retrospective Observational Study.
Item request has been placed!
×
Item request cannot be made.
×
Processing Request
- معلومة اضافية
- المصدر:
Publisher: JMIR Publications Country of Publication: Canada NLM ID: 100959882 Publication Model: Electronic Cited Medium: Internet ISSN: 1438-8871 (Electronic) Linking ISSN: 14388871 NLM ISO Abbreviation: J Med Internet Res Subsets: MEDLINE
- بيانات النشر:
Publication: <2011- > : Toronto : JMIR Publications
Original Publication: [Pittsburgh, PA? : s.n., 1999-
- الموضوع:
- نبذة مختصرة :
Background: Laryngeal microsurgery (LMS) is often accompanied by a sudden increase in blood pressure (BP) during surgery because of stimulation around the larynx. This sudden change in the hemodynamic status is not immediately reflected in a casual cuff-type measurement that takes intermittent readings every 3 to 5 min.
Objective: This study aimed to investigate the potential of pulse arrival time (PAT) as a marker for a BP surge, which usually occurs in patients undergoing LMS.
Methods: Intermittent measurements of BP and electrocardiogram (ECG) and photoplethysmogram (PPG) signals were recorded during LMS. PAT was defined as the interval between the R-peak on the ECG and the maximum slope on the PPG. Mean PAT values before and after BP increase were compared. PPG-related parameters and the correlations between changes in these variables were calculated.
Results: BP surged because of laryngoscopic manipulation (mean systolic BP [SBP] from 115.3, SD 21.4 mmHg, to 159.9, SD 25.2 mmHg; P<.001), whereas PAT decreased significantly (from mean 460.6, SD 51.9 ms, to 405.8, SD 50.1 ms; P<.001) in most of the cases. The change in SBP showed a significant correlation with the inverse of the PAT (r=0.582; P<.001). Receiver-operating characteristic curve analysis indicated that an increase of 11.5% in the inverse of the PAT could detect a 40% increase in SBP, and the area under the curve was 0.814.
Conclusions: During LMS, where invasive arterial catheterization is not always possible, PAT shows good correlation with SBP and may, therefore, have the potential to identify abrupt BP surges during laryngoscopic manipulations in a noninvasive manner.
(©Yong-Seok Park, Sung-Hoon Kim, Yoon Se Lee, Seung-Ho Choi, Seung-Woo Ku, Gyu-Sam Hwang. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 15.05.2020.)
- References:
J Card Surg. 2006 Mar-Apr;21 Suppl 1:S8-S14. (PMID: 16492294)
J Clin Med. 2019 Mar 11;8(3):. (PMID: 30862031)
J Clin Monit Comput. 2011 Dec;25(6):377-85. (PMID: 22051898)
Korean J Anesthesiol. 2017 Feb;70(1):39-45. (PMID: 28184265)
Anesth Analg. 2000 May;90(5):1208-12. (PMID: 10781481)
Anaesthesia. 1995 Feb;50(2):108-13. (PMID: 7710018)
Biomed Opt Express. 2016 Jul 12;7(8):3007-20. (PMID: 27570693)
Ann Otol Rhinol Laryngol. 2003 Apr;112(4):373-8. (PMID: 12731635)
Ann Otol Rhinol Laryngol. 2007 Feb;116(2):107-11. (PMID: 17388233)
Proc ACM Interact Mob Wearable Ubiquitous Technol. 2017 Sep;1(3):. (PMID: 30556049)
ScientificWorldJournal. 2014 Jan 30;2014:353628. (PMID: 24616624)
Physiol Meas. 2010 Feb;31(2):145-57. (PMID: 20009186)
J Clin Hypertens (Greenwich). 2017 Aug;19(8):746-752. (PMID: 28429879)
Hypertension. 2002 Jun;39(6):1083-7. (PMID: 12052846)
J Clin Anesth. 2000 Nov;12(7):509-18. (PMID: 11137411)
J Appl Physiol (1985). 2006 Jan;100(1):136-41. (PMID: 16141378)
J Artif Organs. 2005;8(3):192-7. (PMID: 16235036)
Eur J Appl Physiol. 2012 Jan;112(1):309-15. (PMID: 21556814)
Br J Anaesth. 2006 Jan;96(1):100-5. (PMID: 16257996)
Laryngoscope. 1974 Jun;84(6):908-20. (PMID: 4832373)
J Int Med Res. 2017 Feb;45(1):203-210. (PMID: 28222636)
Korean J Anesthesiol. 2015 Apr;68(2):136-40. (PMID: 25844131)
J Appl Physiol (1985). 2011 Dec;111(6):1681-6. (PMID: 21960657)
Acta Anaesthesiol Scand. 1996 Sep;40(8 Pt 1):883-8. (PMID: 8908222)
J Med Syst. 2016 Sep;40(9):195. (PMID: 27447469)
Eur J Appl Physiol. 2011 Jan;111(1):135-44. (PMID: 20824282)
Anesth Analg. 2002 Aug;95(2):273-7, table of contents. (PMID: 12145033)
Medicine (Baltimore). 2017 Jun;96(22):e7045. (PMID: 28562562)
J Clin Anesth. 1996 Feb;8(1):63-79. (PMID: 8695083)
Sci Rep. 2018 Jan 24;8(1):1527. (PMID: 29367620)
Anesth Analg. 2013 Jan;116(1):94-100. (PMID: 23223109)
Br J Anaesth. 2004 Apr;92(4):570-83. (PMID: 15013960)
Br J Anaesth. 1987 Mar;59(3):295-9. (PMID: 3828177)
Electroencephalogr Clin Neurophysiol. 1992 May;82(5):391-3. (PMID: 1374708)
Clin Res Cardiol. 2010 Oct;99(10):657-64. (PMID: 20473677)
Circ Res. 2014 May 23;114(11):1804-14. (PMID: 24855203)
Psychophysiology. 1981 Jan;18(1):71-4. (PMID: 7465731)
Int Conf Signal Process Proc. 2014 Oct;2014:115-118. (PMID: 26213717)
Ann Otol Rhinol Laryngol. 1997 Oct;106(10 Pt 1):863-8. (PMID: 9342984)
J Clin Monit Comput. 2004 Dec;18(5-6):333-42. (PMID: 15957624)
- Contributed Indexing:
Keywords: blood pressure; larynx; photoplethysmography; pulse
- الموضوع:
Date Created: 20200516 Date Completed: 20201117 Latest Revision: 20201117
- الموضوع:
20231215
- الرقم المعرف:
PMC7260662
- الرقم المعرف:
10.2196/13156
- الرقم المعرف:
32412413
No Comments.