Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Estimation of gestational age, using neonatal anthropometry: a cross-sectional study in India.

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • المصدر:
      Publisher: BioMedCentral Country of Publication: Bangladesh NLM ID: 100959228 Publication Model: Print Cited Medium: Print ISSN: 1606-0997 (Print) Linking ISSN: 16060997 NLM ISO Abbreviation: J Health Popul Nutr Subsets: MEDLINE
    • بيانات النشر:
      Publication: May 2015- : London: BioMedCentral
      Original Publication: Dhaka, Bangladesh : ICDDR,B: Centre for Health and Population Research, c2000-
    • الموضوع:
    • نبذة مختصرة :
      Prematurity is a significant contributor to neonatal mortality in India. Conventionally, assessment of gestational age of newborns is based on New Ballard Technique, for which a paediatric specialist is needed. Anthropometry of the newborn, especially birthweight, has been used in the past to predict the gestational age of the neonate in peripheral health facilities where a trained paediatrician is often not available. We aimed to determine if neonatal anthropometric parameters, viz. birthweight, crown heel-length, head-circumference, mid-upper arm-circumference, lower segment-length, foot-length, umbilical nipple distance, calf-circumference, intermammary distance, and hand-length, can reliably predict the gestational age. The study also aimed to derive an equation for the same. We also assessed if these neonatal anthropometric parameters had a better prediction of gestational age when used in combination compared to individual parameters. We evaluated 1,000 newborns in a cross-sectional study conducted in Guru Teg Bahadur Hospital in Delhi. Detailed anthropometric estimation of the neonates was done within 48 hours after birth, using standard techniques. Gestational age was estimated using New Ballard Scoring. Out of 1,250 consecutive neonates, 1,000 were included in the study. Of them, 800 randomly-selected newborns were used in devising the model, and the remaining 200 newborns were used in validating the final model. Quadratic regression analysis using stepwise selection was used in building the predictive model. Birthweight (R=0.72), head-circumference (R = 0.60), and mid-upper arm-circumference (R = 0.67) were found highly correlated with gestation. The final equation to assess gestational age was as follows: Gestational age (weeks) = 5.437 x W-0.781 x W(2) + 2.815 x HC-0.041 x HC(2) + 0.285 x MUAC-22.745 where W=Weight, HC=Head-circumference and MUAC=Mid-upper arm-circumference; Adjusted R = 0.76. On validation, the predictability of this equation is 46% (+/-1 week), 75.5% (+/- 2 weeks), and 91.5% (+/- 3 weeks). This mathematical model may be used in identifying preterm neonates.
    • References:
      Lancet. 1994 Aug 20;344(8921):524-7. (PMID: 7914620)
      Am J Obstet Gynecol. 2002 Dec;187(6):1660-6. (PMID: 12501080)
      J Natl Med Assoc. 2004 Aug;96(8):1092-6. (PMID: 15303415)
      Bull World Health Organ. 2010 Jan;88(1):31-8. (PMID: 20428351)
      Indian J Public Health. 2011 Oct-Dec;55(4):298-302. (PMID: 22298139)
      Cad Saude Publica. 2000 Jan-Mar;16(1):83-94. (PMID: 10738153)
      Rev Epidemiol Sante Publique. 2010 Dec;58(6):409-14. (PMID: 21094002)
      Lancet. 2005 Mar 5-11;365(9462):891-900. (PMID: 15752534)
      Arch Dis Child. 2006 May;91(5):410-3. (PMID: 16464960)
      J Pediatr. 1986 Aug;109(2):311-5. (PMID: 3734968)
      Lancet. 2004 Jul 31-Aug 6;364(9432):399-401. (PMID: 15288723)
      Pediatrics. 1963 Nov;32:793-800. (PMID: 14075621)
      Ann Trop Paediatr. 2010;30(3):197-204. (PMID: 20828452)
      BMC Pediatr. 2008 Apr 25;8:16. (PMID: 18439237)
      Int J Nurs Stud. 2009 Mar;46(3):310-6. (PMID: 19019368)
      Early Hum Dev. 1985 Jul;11(2):169-78. (PMID: 4029053)
    • الموضوع:
      Date Created: 20140306 Date Completed: 20140403 Latest Revision: 20220317
    • الموضوع:
      20221213
    • الرقم المعرف:
      PMC3905647
    • الرقم المعرف:
      10.3329/jhpn.v31i4.20051
    • الرقم المعرف:
      24592594