T2*-weighted imaging for detection of intracranial silicone oil in MRI obtained with motion correction sequences.
Item request has been placed!
×
Item request cannot be made.
×

Processing Request
- المؤلفون: Yasuda, Ryuta1,2 (AUTHOR) ; Maeda, Masayuki3,4 (AUTHOR); Takada, Kenichi3 (AUTHOR); Inoue, Katsuhiro4 (AUTHOR); Sugao, Masataka5 (AUTHOR); Suzuki, Hidenori2 (AUTHOR)
- المصدر:
Egyptian Journal of Neurosurgery. 2/6/2025, Vol. 40 Issue 1, p1-6. 6p.
- الموضوع:
- معلومة اضافية
- نبذة مختصرة :
المقال يركز على فعالية التصوير المعتمد على T2*-weighted imaging (T2*WI) في الكشف عن هجرة زيت السيليكون داخل الجمجمة باستخدام التصوير بالرنين المغناطيسي (MRI) مع تسلسلات تصحيح الحركة، وبالتحديد MultiVane XD. يقدم دراسة حالة لمريضة تبلغ من العمر 77 عامًا عانت من اضطرابات في الوعي بسبب هجرة زيت السيليكون بعد إجراء جراحة العين. وجدت الدراسة أن T2*WI كانت التسلسل الأكثر حساسية للكشف عن زيت السيليكون، متفوقة على تسلسلات MRI الأخرى مثل التصوير المعتمد على T1 (T1WI)، والتصوير المعتمد على T2 (T2WI)، واستعادة الانقلاب المخفف للسوائل (FLAIR). تشير النتائج إلى أن قدرة T2*WI على تصوير فنون الحساسية تجعلها مفيدة بشكل خاص في الحالات التي تعقد فيها حركة المريض عملية التصوير. [Extracted from the article]
- نبذة مختصرة :
Background: For magnetic resonance imaging (MRI) findings of intracranial silicone oil migration, little has been described about images obtained with motion correction sequences such as MultiVane XD (Philips Healthcare) that provides high resolution diagnostic images even with severe patient motion. We report a case with intracranial silicone oil migration in which MRI was obtained with MultiVane XD and T2*-weighted imaging (T2*WI) was found the most useful in detecting intracranial silicone oil. Case presentation: A 77-year-old female with a history of eye surgery using silicone oil referred to our hospital due to conscious disturbance. Head computed tomography demonstrated multiple intracranial masses whose signal density was similar to that in the operated eyeball and the tentative diagnosis of intracranial silicone oil migration was made. MRI was performed with MultiVane XD due to the significant patient's restlessness, and among all sequences including T1-weighted imaging (T1WI), T2-weighted imaging (T2WI), fluid-attenuated inversion recovery (FLAIR) and T2*WI, only T2*WI detected intracranial silicone oil. In contrast, another MRI obtained previously with conventional turbo spin-echo detected intracranial silicone oil not only in T2*WI but also in T1WI, T2WI and FLAIR. Phantom experiment revealed that chemical shift artifact played an important role in discriminating silicone oil from artificial cerebrospinal fluid, which attenuated in MultiVane XD. However, T2*WI still showed good discrimination of silicone oil even using MultiVane XD because of susceptibility artifacts. Conclusion: T2*WI was the best sequence to detect intracranial silicone oil in MRI obtained with motion correction sequences because of its ability to depict the susceptibility artifacts. [ABSTRACT FROM AUTHOR]
- نبذة مختصرة :
Copyright of Egyptian Journal of Neurosurgery is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)