Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Effects of Medium-Term Soft Contact Lens Fitting on Dry Eye: Analyses Using Ultra-High Resolution Optical Coherence Tomography and Digital Slit-Lamp Biomicroscopy.

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • نبذة مختصرة :
      Purpose. This study aimed to evaluate the medium-term fit of soft contact lenses (SCLs) and its effects on dry eye by using ultra-high-resolution optical coherence tomography (UHR-OCT) and digital slit-lamp biomicroscopy (DSLB) and identify factors indicating a better contact lens fit. Methods. A total of 14 participants (7 men, 7 women; mean age, 23.1 years) were recruited. Temporal lag and conjunctival coverage were imaged by UHR-OCT. DSLB was used to assess lens decentration and blink-induced movement. In addition, dry eye indices, including ocular surface disease index (OSDI), tear break-up time (TBUT), and Schirmer I test scores, were measured at baseline and 1 day, 1 week, 1 month, 3 months, and 6 months after wearing. Results. Good repeatability was found in the assessments of lens fit characteristics by two researchers and in the assessments by one researcher at different follow-up times. There were no significant differences in lens fit characteristics, TBUT and Schirmer I test scores at each checkpoint (P >0.05). However, the OSDI was significantly higher than baseline after wearing (P <0.05). Changes in the temporal lag were positively correlated with changes in TBUT (r =0.544, P =0.044) and negatively correlated with changes in OSDI (r = -0.629, P =0.016). Changes in blink-induced movement were positively correlated with changes in OSDI, Schirmer I test scores, and TBUT (P <0.05). Conclusions. UHR-OCT and DSLB can be used to comprehensively and quantitatively evaluate SCL fit. Both the contact lenses and ocular surface conditions are almost stable within 6 months of SCL wear. Temporal lag and blink-induced movement have a strong correlation with dry eye parameters in SCL wearers. [ABSTRACT FROM AUTHOR]
    • نبذة مختصرة :
      Copyright of Disease Markers is the property of Hindawi Limited and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)