Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Nerve conduction block utilising high-frequency alternating current.

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • المؤلفون: Kilgore, K. L.; Bhadra, N.
  • المصدر:
    Medical & Biological Engineering & Computing. May2004, Vol. 42 Issue 3, p394-406. 13p. 3 Diagrams, 7 Graphs.
  • معلومة اضافية
    • الموضوع:
    • نبذة مختصرة :
      High-frequency alternating current (AC) waveforms have been shown to produce a quickly reversible nerve block in animal models, but the parameters and mechanism of this block are not well understood. A frog sciatic nerve/gastrocnemius muscle preparation was used to examine the parameters for nerve conduction block in vivo, and a computer simulation of the nerve membrane was used to identify the mechanism for block. The results indicated that a 100% block of motor activity can be accomplished with a variety of waveform parameters, including sinusoidal and rectangular waveforms at frequencies from 2 kHz to 20 kHz. A complete and reversible block was achieved in 34 out of 34 nerve preparations tested. The most efficient waveform for conduction block was a 3-5 kHz constant-current biphasic sinusoid, where block could be achieved with stimulus levels as low as 0.01 microCphase(-1). It was demonstrated that the block was not produced indirectly through fatigue. Computer simulation of high-frequency AC demonstrated a steady-state depolarisation of the nerve membrane, and it is hypothesised that the conduction block was due to this tonic depolarisation. The precise relationship between the steady-state depolarisation and the conduction block requires further analysis. The results of this study demonstrated that high-frequency AC can be used to produce a fast-acting, and quickly reversible nerve conduction block that may have multiple applications in the treatment of unwanted neural activity. [ABSTRACT FROM AUTHOR]
    • نبذة مختصرة :
      Copyright of Medical & Biological Engineering & Computing is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)