Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Characterization of the thrombin generation potential of leukemic and solid tumor cells by calibrated automated thrombography

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • الموضوع:
      2012
    • Collection:
      Maastricht University Research Publications
    • نبذة مختصرة :
      Background Thrombin, the final enzyme of blood coagulation, is a multifunctional serine protease also involved in the progression of cancer. Tumor cells may activate blood coagulation proteases through the expression of procoagulant activities. However, specific information about the thrombin generation potential of malignant tissues is lacking. In this study we applied a single global coagulation test, the calibrated automated thrombogram assay, to characterize the specific procoagulant phenotypes of different tumor cells. Design and Methods Malignant hematologic cells (i.e. NB4, HEL, and K562) or solid tumor cells (i.e. MCF-7 breast cancer and H69 small cell lung cells) were selected for the study. The calibrated automated thrombogram assay was performed in normal plasma and in plasma samples selectively deficient in factor VII, XII, IX or X, in the absence or presence of a specific anti-tissue factor antibody. Furthermore, cell tissue factor levels were characterized by measuring antigen, activity and mRNA expression. Results In normal plasma, NB4 induced the highest thrombin generation, followed by MCF-7, H69, HEL, and K562 cells. The anti-tissue factor antibody, as well as deficiencies of factors VII, IX and XII affected the thrombin generation potential of malignant cells to different degrees, allowing differentiation of the two different pathways of blood clotting activation - by tissue factor or contact activation. The thrombin generation capacity of NB4 and MCF-7 cells was tissue factor-dependent, as it was highly sensitive to inhibition by anti-tissue factor antibody and factor VII deficiency, while the thrombin generation capacity of H69, HEL and K562 was contact activation-dependent, as no thrombin was generated by these cells in factor XII-deficient plasma. Conclusions This study demonstrates that the calibrated automated thrombogram assay is capable of quantifying, characterizing, and comparing the thrombin generation capacity of different tumor cells. This provides a useful tool for understanding ...
    • ISSN:
      0390-6078
      1592-8721
    • Relation:
      info:eu-repo/semantics/altIdentifier/pmid/22419573; info:eu-repo/semantics/altIdentifier/wos/000307524100010; info:eu-repo/semantics/altIdentifier/pissn/0390-6078; info:eu-repo/semantics/altIdentifier/eissn/1592-8721
    • الرقم المعرف:
      10.3324/haematol.2011.055343
    • الدخول الالكتروني :
      https://cris.maastrichtuniversity.nl/en/publications/27d2af68-ecdd-49ee-8367-2e668aeae693
      https://doi.org/10.3324/haematol.2011.055343
    • Rights:
      info:eu-repo/semantics/openAccess ; http://creativecommons.org/licenses/by-nc/4.0/
    • الرقم المعرف:
      edsbas.F798F161