Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Adaptação e validação da escala de capacidades do cuidador informal de idosos dependentes por AVC (ECCIID-AVC) para uso no Brasil

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • Thesis Advisors:
      Paskulin, Lisiane Manganelli Girardi
    • بيانات النشر:
      publishedVersion
    • الموضوع:
      2018
    • Collection:
      IBICT Brazilian ETDs
    • Original Material:
      001068024
    • نبذة مختصرة :
      O Acidente Vascular Cerebral (AVC) é a doença cerebrovascular mais prevalente na população idosa e uma das principais causas de incapacidade funcional. A Escala de Capacidades do Prestador Informal de Cuidados de Idosos Dependentes por AVC (ECPICID-AVC), desenvolvida em Portugal, avalia 32 capacidades que cuidadores informais devem possuir para apoiar os idosos sobreviventes de AVC. O objetivo deste estudo foi adaptar e validar a escala ECPICID-AVC para uso com cuidadores informais de pessoas idosas sobreviventes de AVC no Brasil. Trata-se de estudo metodológico dividido em duas etapas: adaptação transcultural e validação. A adaptação transcultural contou com as subetapas: Comitê de Especialistas, Pré- Teste e Submissão do documento aos autores do instrumento original. A validação envolveu coleta de dados e avaliação das propriedades psicométricas. A pesquisa foi realizada no Hospital de Clínicas de Porto Alegre (HCPA) e Grupo Hospitalar Conceição (GHC). Para avaliação das propriedades psicométricas foram verificadas as características de fidedignidade e a validade dos resultados (validades de conteúdo e constructo). A consistência interna dos itens que compõem a escala foi investigada por meio do alfa de Cronbach e da Correlação Intraclasse (ICC) A validade de constructo foi avaliada pela análise fatorial exploratória. O projeto foi aprovado pelos Comitês de Ética em Pesquisa do HCPA (n° 160580) e do GHC (nº 17152). Na etapa de adaptação transcultural, após as considerações do comitê de especialistas e a aprovação do autor da ECPICID-AVC, a versão pré-teste foi avaliada em uma amostra de 30 cuidadores e os termos considerados de menor entendimento foram adequados. A versão final da Escala de Capacidades do Cuidador Informal de Idosos Dependentes por AVC (ECCIID-AVC) foi aplicada a 160 cuidadores, sendo 82,5% mulheres com idade média de 49,6 ± 13,1 anos. A análise fatorial sugeriu a exclusão de três itens e o agrupamento dos demais em seis domínios, explicando 70,52% da variância total. Foram encontradas cargas fatoriais variando de 0,525 a 0,924. A consistência interna intra-avaliadores foi satisfatória, com coeficiente de correlação intraclasse de 0,94 (IC 95%). A confiabilidade total foi considerada excelente (alfa Cronbach = 0,914). Considera-se a escala adaptada e válida para uso no contexto brasileiro para aplicação na prática clínica e na pesquisa.
      Stroke is the most prevalent cerebrovascular disease and one of the leading causes of functional disability in aged population. The Portuguese instrument for informal caregivers’ skills providing care of aged people after a stroke (ECPICID-AVC) evaluates the capacities that informal caregivers must have for supporting aged stroke survivors. The purpose of this study was to adapt and validate the ECPICID-AVC for using with informal caregivers of older adult stroke survivors in Brazil. It is a methodological study divided in two stages: cross-cultural adaptation and validation. The cross-cultural adaptation was divided in sub-stages: Committee of Experts, Pre-Test and Submission of the document to the authors of the original instrument. Validation involved data collection and evaluation of psychometric properties. The research was carried out at the Hospital de Clínicas de Porto Alegre (HCPA) and Grupo Hospitalar Conceição (GHC). The reliability characteristics and the validity of the results (content and construct validities) were verified for evaluating psychometric properties. The internal consistency of the instrument items was investigated using the Cronbach's Alpha and the Intraclass Correlation (ICC) The construct validity was evaluated by the exploratory factorial analysis. The project was approved by the Research Ethics Committees of HCPA (n° 160580) and GHC (nº 17152). After the considerations of the committee of Experts and the approval of the author of ECPICID-AVC, in the transcultural adaptation stage the pre-test version was evaluated in a sample of 30 caregivers and the terms considered of lesser understanding were adequate. The final version of the instrument was applied to 160 caregivers, 82.5% were women with a mean age of 49.6 ± 13.1 years. The factorial analysis suggested exclusion of three items and grouping of the others in six domains, explaining 70.52% of the total variance. Factorial loads ranging from 0.525 to 0.924 were found. Intra-rater internal consistency was satisfactory, with ICC = 0.94 (95% CI). Total reliability was considered excellent (Cronbach’s Alpha = 0.914). The instrument is considered adapted and valided for using in the Brazilian context for application in clinical practice and research.
      El Accidente Cerebrovascular (ACV) es la enfermedad cerebrovascular más prevalente en la población anciana y una de las principales causas de incapacidad funcional. La Escala de Capacidades del Proveedor Informal de Atención a los Ancianos Dependientes por ACV (ECPICID-AVC), desarrollada en Portugal, evalúa las 32 habilidades que los cuidadores informales deben tener para apoyar los ancianos sobrevivientes de accidentes cerebrovasculares. Así, este estudio tuvo como objetivo adaptar y validar del instrumento ECPICID-AVC para utilización con cuidadores informales de personas ancianas sobrevivientes de ACV en Brasil. Se trata de un estudio metodológico dividido en dos etapas: adaptación transcultural y validación. La adaptación transcultural contó con las subtepas: Comité de expertos, Pre-Prueba y Sumisión del documento a los autores del instrumento original. La validación incluyó la recolección de datos y la evaluación de las propiedades psicométricas. La investigación se llevó a cabo en el Hospital de Clínicas de Porto Alegre (HCPA) y en el Grupo Hospitalario Conceição (GHC). Para evaluar las propiedades psicométricas, se verificaron las características de fiabilidad y la validez de los resultados (valideces de contenido y constructo) La consistencia interna de los elementos que componen del instrumento se verificó por medio del alfa de Cronbach y de la Correlación Intraclasse (ICC, su acrónimo en inglés). La validez de constructo se evaluó por el análisis factorial exploratorio. El proyecto fue aprobado por los Comités de Ética en Investigación del HCPA (nº 160580) y del GHC (nº 17152). En la etapa de adaptación transcultural, después de las consideraciones del comité de expertos y la aprobación del autor del instrumento, la versión pre-prueba fue evaluada en una muestra de 30 cuidadores, y los términos considerados de menor comprensión fueron adecuados. La versión final del instrumento fue aplicada a 160 cuidadores, de los cuales el 82,5% eran mujeres, con edad promedio de 49,6 ± 13,1 años. El análisis factorial ha sugerido la exclusión de tres elementos y la agrupación de los demás en seis dominios, lo que explica el 70,52% de la varianza total. Se hallaron cargas factoriales variando de 0,525 a 0,924. La consistencia interna intra-evaluadores fue satisfactoria, con coeficiente de correlación intraclase de 0,94 (IC 95%). La fiabilidad total fue considerada excelente (alfa de Cronbach = 0,914). El instrumento se considera adaptado y válido para utilización en el contexto brasileño para aplicación en la práctica clínica y en la investigación.
    • الرقم المعرف:
      oai:www.lume.ufrgs.br:10183/179384
    • File Description:
      application/pdf
    • Rights:
      info:eu-repo/semantics/openAccess
    • الرقم المعرف:
      edsndl.IBICT.oai.www.lume.ufrgs.br.10183.179384