Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Long-term stability and resistance to fracture: Different abutments of the SIC implant system in the artificial mouth

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • المؤلفون: Al-Sahhaf, Abdul Aziz
  • نوع التسجيلة:
    doctoral or postdoctoral thesis
  • اللغة:
    English
  • معلومة اضافية
    • الموضوع:
      2016
    • Collection:
      University of Freiburg: FreiDok
    • نبذة مختصرة :
      Objective To investigate the survival rate, fracture strength, bending moments, loading to fracture and fracture modes of different designs of zirconia abutments after dynamic loading with thermocycling, and compare these values to titanium abutments. Methods A total of 80 abutment samples were divided into 5 test groups of 16 samples in each group. The study included the following groups, Group 1: CAD/CAM produced all-zirconia abutments, Group 2: titanium abutments, Group 3 zirconia-abutments adhesively luted to a titanium base, Group 4: prefabricated all-zirconia abutments and Group 5: zirconia-abutments glass soldered to a titanium base. Half the number of samples in each group was exposed to 1.2 million loading cycles (5-years simulation) in the chewing simulator. The samples that survived the artificial aging were later tested for fracture strength in a universal testing machine. The remaining 8 samples of the group were directly tested for fracture strength. Results All samples exposed to the 5-years artificial aging survived except of six samples in one group (Group 1). The surviving samples were later fracture tested in the universal testing machine. The bending moments (Ncm) values were as follow: Exposed groups: Group 1: 94.5 Ncm; Group 2: 599.2 Ncm; Group 3: 477.5 Ncm; Group 4: 314.4 Ncm; Group 5: 509.4 Ncm. Non-exposed groups: Group 1: 269.3 Ncm; Group 2: 474.2 Ncm; Group 3: 377.6 Ncm; Group 4: 265.4 Ncm; Group 5: 372.4 Ncm. Except in Group 1, the values were higher in the exposed groups, although, statistically there was no difference (p>0.05). The one-piece ZrO2-abutment group (Group 1 and Group 4) exhibited lower values, while the two-piece ZrO2-abutment groups (Group 3 and Group 5) showed similar values and fracture modes like the titanium abutment group. The titanium abutment group showed the highest values of bending moments among all groups. Conclusion The implant-abutment connection area appeared to influence the bending moment value and the fracture mode of the tested abutment ...
    • File Description:
      pdf
    • Relation:
      https://freidok.uni-freiburg.de/data/11314
    • الرقم المعرف:
      10.6094/UNIFR/11314
    • الدخول الالكتروني :
      https://freidok.uni-freiburg.de/data/11314
      https://nbn-resolving.org/urn:nbn:de:bsz:25-freidok-113146
      https://doi.org/10.6094/UNIFR/11314
      https://freidok.uni-freiburg.de/dnb/download/11314
    • Rights:
      free
    • الرقم المعرف:
      edsbas.E600EBE1